Gara europea a procedura aperta soprasoglia per l'affidamento della fornitura di n. 173 (centosettantatre) basamenti in granito per i girder dell'anello di accumulazione per il progetto Elettra 2.0. Gara europea a procedura aperta soprasoglia per l'affidamento della fornitura di n. 173 (centosettantatre) basamenti in granito per i girder dell'anello di …
In total, there are 9 oval and branching vacuum chambers of different chamber types. The special quadrupole chambers consist out of two elliptical tubes with two DN160CF flanges, connected to a rectangular body with two DN160CF and one DN400CF flange. In addition, each vacuum chamber must include all necessary components …
Für das FAIR-Projekt an der GSI sind neue Entwicklungen im Bereich der Strahldiagnostik notwendig, um das erweiterte Spektrum der Strahlparameter abzudecken. In den Speicherringen können die Strahlintensitäten - insbesondere während der Inbetriebnahme - weit unter 1 µA liegen, was dem Detektionsbereich regulärer Strahltransformatoren entspricht. Die langsam extrahierten Strahlen aus dem …
In total, there are 124 straight vacuum chambers of different chamber types. The straight vacuum chambers are equipped with two DN160CF and some with DN200CF flanges. Some chambers require a fixed bellow either on one side or on both sides of the chamber. In addition, each vacuum chamber must include …
1.Przedmiotem niniejszego zamówienia jest dostawa systemu tarczy do produkcji izotopów metali przejściowych w postaci ciekłej, zestawu aparatury do wysokosprawnej chromatografii cieczowej, kriostatu półautomatycznego z wbudowanym mikrotomem dla Narodowego Instytutu Onkologii im. Marii Skłodowskiej-Curie – Państwowego Instytutu Badawczego Oddziału w Gliwicach zwanego dalej Zamawiającym. 2. Opis przedmiotu zamówienia oraz warunki realizacji …
Rahmenvertrag über Einkoppelschleifen über 4 Jahre Einkoppelschleifen
The DN400CF hydroformed bellows assemblies of the Super-FRS beamline are designed to operate at room temperature under an ultimate pressure below 10?7 mbar. These hydroformed bellows assemblies function as flexible and adaptable connections between adjacent vacuum components, ensuring vacuum integrity while accommodating mechanical tolerances and thermal expansion. A total of …
SIS100 will be equipped with a halo collimation system to remove unwanted halo particles and catch systematic losses caused by the extraction process. It is required to protect sensitive accelerator components from unavoidable beam loss. Among other components, the halo collimation system consists of moveable collimator blocks. The movability is …
Le présent marché concerne la réalisation de cavités accélératrices supraconductrices elliptiques ; dénommées « cavité/réservoir ». La consultation donnera lieu à un marché à tranches, réparti de la façon suivante : Tranche ferme (TF) : Fourniture : • 1 cavité nue 1-cellule (Figure 1 du CCTP) ; • 4 ensembles …
The pumping chambers serve as the interface for the ion getter pumps and vacuum diagnostic components of the Super-FRS beamline. It shall also be equipped with one or two bellows, three pumping ports, and a vacuum diagnostic port. The DN400CF pumping chambers with integrated hydroformed bellows of the Super-FRS beamline …