Description
:
TPC1: Information on the execution of relevant and comparable services (= tenderer references) where the main activities were conducted within a maximum of eight (8) years prior to the publication of the notice. At least 3 particularly relevant references must be submitted, whereby the references must cover and fulfill the three mentioned competencies (Competence 1, Competence 2, Competence 3) with at least 5 of the mentioned skills each. A reference can only fulfill one of the three possible competencies, although multiple references can come from the same contracting authority. A comprehensible description of the reference is required (max. two (2) pages per reference in DIN A4, font: Arial, font size 11, as pdf. -file). A reference is considered comparable, in particular, when it involves services that allow conclusions about the candidates suitability based on size and complexity. It should be noted that a reference project, for the purposes of this self-declaration, is comparable if the following services were performed in the reference project(s): Competence 1: Tenderer has experience with the EPC-M role for a large diameter (>24 in) long distance (>200km) gas pipeline system including successful completion. For each reference provided (minimum and additional references), the following criteria must be fulfilled: As a minimum 50.000 hours of work for the Contracting authority or EUR 5,000,000, excluding VAT, for the work for the Contracting Authority. For each reference provided (minimum and additional references), a minimum of 5 of the engineering areas/skills mentioned below must be fulfilled: Engineering Management, Technical/Process Safety, Contract Management, Procurement Management, Construction Supervision, Interface Management, Design Review, Permitting experience (indicate if in Northsea), Platform and subsea structure management. Competence 2: Tenderer has experience with the design of offshore gas (incl. hydrogen) pipeline systems (>24-in, >200km). For each reference provided (minimum and additional references), the following criteria must be fulfilled: As a minimum pre-FEED (not concept phase) for hydrogen, min. FEED for hydrocarbon gas. As a minimum 10.000 hours of work for the Contracting authority or EUR 1,000,000, excluding VAT, for the work for the Contracting Authority. For each reference provided (minimum and additional references), a minimum of 5 of the engineering areas/skills mentioned below must be fulfilled: Engineering, Routing, Materials Design and Qualification, Survey Contracting & Management, Mechanical design, Platforms and Subsea Structures, Shorecrossing, Permitting experience (indicate if in Northsea), Competence 3: Tenderer has experience with the design of offshore process platforms, subsea structures, including process, safety, electrical, and structural/lay-out For each reference provided (minimum and additional references), the following criteria must be fulfilled: As a minimum FEED phase As a minimum 20.000 hours of work for the Contracting authority or EUR 2,000,000, excluding VAT, for the work for the Contracting Authority. For each reference provided (minimum and additional references), a minimum of 5 of the engineering areas/skills mentioned below must be fulfilled: Engineering Management, Process Engineering, Technical/Process Safety, Equipment/Mechanical Engineering, Lay-out/Structural Engineering, Materials and design, Instrumentation and automation engineering, Electronical engineering. The following must be submitted for all three Competencies (Competence 1, Competence 2, Competence 3): Each reference must include at least the following information to demonstrate comparability: Reference Title Contracting Authority Contact Person including contact data Description of services provided Value in EUR (net) Period of execution For each reference, a comprehensible description of the reference is required (max. 2 pages per reference in DIN A4, font: Arial, font size 11, as pdf. -file). Minimum Requirement (Failure to meet will result in exclusion): At least 3 particularly relevant references must be submitted, whereby the references must cover and fulfill the three mentioned competencies (Competence 1, Competence 2, Competence 3) with at least 5 of the mentioned skills each. A reference can only fulfill one of the three possible competencies, although multiple references can come from the same contracting authority. Refer to Appendix A.1 Forms and Proofs (Qualitative Selection), Form 7. TPC2: Self-declaration average annual number of employees in the executing office location in the last three years Candidates staff resources in the relevant disciplines to which the invitation to tender is related shall be at least 300 in the executing office location (excluding contractors/non-staff). Each discipline and number for each executing office location must be recorded separately. Regarding the executing office a distinction must be made between permanent staff and contractor personnel. The disciplines must include at least the following disciplines: project management, process, materials, mechanical, piping/lay-out, civil/structural, instrumentation and controls, electrical, process safety, HSSE, Quality, offshore pipeline, procurement, construction management. Minimum Requirement (Failure to meet will result in exclusion): The average annual number of employes in the executing office location in the last three years must be at least 300 (excluding contractors/non-staff). Refer to Appendix A.1 Forms and Proofs (Qualitative Selection), Proof 4.