MYTHENIII 24K strip detector

DTU intends to procure a MYTHENIII microstrip detector system consisting of: - 24 MYTHENIII modules (1280 channels, 450 µm Si sensor) including transceivers. - Support and training during installation. - Technical support during the first year of operation. DTU will procure an X-ray microstrip detector for use on the DanMAX …

CPV: 38432300 Smoke-analysis apparatus
Place of execution:
MYTHENIII 24K strip detector
Awarding body:
Danmarks Tekniske Universitet - DTU
Award number:
6722

1. Køber

1.1 Køber

Officielt navn : Danmarks Tekniske Universitet - DTU
Køberens retlige status : Offentligretligt organ
Den ordregivende myndigheds aktivitet : Uddannelse

2. Procedure

2.1 Procedure

Titel : MYTHENIII 24K strip detector
Beskrivelse : DTU intends to procure a MYTHENIII microstrip detector system consisting of: - 24 MYTHENIII modules (1280 channels, 450 µm Si sensor) including transceivers. - Support and training during installation. - Technical support during the first year of operation. DTU will procure an X-ray microstrip detector for use on the DanMAX beamline at the MAX IV 3GeV synchrotron storage ring located in Lund, Sweden. The detector will be used for high-resolution powder X-ray diffraction. To fulfill the scientific requirements agreed with the funders, the detector must be of the Hybrid Pixel Array Detector (HPAD) type, as this technology has a superior signal-to-noise ratio and dynamic range compared to all other area detector technologies available. It must be a 1D microstrip detector with a channel pitch of no more than 50 µm pitch to obtain the angular resolution required. Essential properties and specifications: Due to the very high X-ray flux at the DanMAX beamline, and to allow use of its full ability, it is im-perative that the count rate of the detector is as high as possible. The MYTHENIII system has a higher count rate than any other microstrip detectors available. Other beamlines with significantly lower flux are today limited by the commercially available detectors of this type. The MYTHENIII system further offers three independent thresholds that can be used to analyze pile-up, which can improve the count rate even further to ensure that we can use the high flux at DanMAX. The DanMAX beamline is built without higher harmonic rejection mirrors. To obtain the desired data quality the detector must have at least two, preferably three, thresholds for discriminating against higher harmonic contamination in the beam. Similarly, multiple thresholds will be used for fluorescence discrimination. The MYTHENIII system has three independent thresholds, whereas other available systems have only one and thus does not allow for higher harmonic rejection. The noise level is critical for the application and must be as low as possible. As the beamline operates at various energies the flat field must show minimal changes at various energies. In this regard, the MYTHENIII system is superior to commercial strip detectors. Advantages over other systems, potential for future developments: The MYTHENIII system has a much higher frame rate than commercially available detectors. This will be highly beneficial as it allows for faster time-resolved experiments. The detector will be used in the energy range 15-35 keV. At the higher photon energies the Si sen-sor will be less efficient due to lower absorption. It is preferred that the detector can be upgraded to a high-Z sensor if this technology becomes available. The MYTHENIII electronics is prepared for such an upgrade. No other available systems offer this upgradability.
Identifikator for proceduren : 93ae0da6-7b05-4124-9c23-d9ee60bd9eda
Intern ID : 6722
Udbudsprocedure : Udbud med forhandling uden forudgående offentliggørelse

2.1.1 Formål

Kontraktens hovedformål : Varer
Primær klassifikation ( cpv ): 38432300 Røganalyseringsapparat

2.1.2 Udførelsessted

Postadresse : Fotongatan 8
By : Lund
Postnummer : 22484
Landsdel (NUTS) : Skåne län ( SE224 )
Land : Sverige

2.1.4 Generelle oplysninger

Retsgrundlag :
Direktiv 2014/24/EU

5. Delkontrakt

5.1 Teknisk ID for delkontrakten : LOT-0000

Titel : MYTHENIII 24K strip detector
Beskrivelse : DTU intends to procure a MYTHENIII microstrip detector system consisting of: - 24 MYTHENIII modules (1280 channels, 450 µm Si sensor) including transceivers. - Support and training during installation. - Technical support during the first year of operation. DTU will procure an X-ray microstrip detector for use on the DanMAX beamline at the MAX IV 3GeV synchrotron storage ring located in Lund, Sweden. The detector will be used for high-resolution powder X-ray diffraction. To fulfill the scientific requirements agreed with the funders, the detector must be of the Hybrid Pixel Array Detector (HPAD) type, as this technology has a superior signal-to-noise ratio and dynamic range compared to all other area detector technologies available. It must be a 1D microstrip detector with a channel pitch of no more than 50 µm pitch to obtain the angular resolution required. Essential properties and specifications: Due to the very high X-ray flux at the DanMAX beamline, and to allow use of its full ability, it is im-perative that the count rate of the detector is as high as possible. The MYTHENIII system has a higher count rate than any other microstrip detectors available. Other beamlines with significantly lower flux are today limited by the commercially available detectors of this type. The MYTHENIII system further offers three independent thresholds that can be used to analyze pile-up, which can improve the count rate even further to ensure that we can use the high flux at DanMAX. The DanMAX beamline is built without higher harmonic rejection mirrors. To obtain the desired data quality the detector must have at least two, preferably three, thresholds for discriminating against higher harmonic contamination in the beam. Similarly, multiple thresholds will be used for fluorescence discrimination. The MYTHENIII system has three independent thresholds, whereas other available systems have only one and thus does not allow for higher harmonic rejection. The noise level is critical for the application and must be as low as possible. As the beamline operates at various energies the flat field must show minimal changes at various energies. In this regard, the MYTHENIII system is superior to commercial strip detectors. Advantages over other systems, potential for future developments: The MYTHENIII system has a much higher frame rate than commercially available detectors. This will be highly beneficial as it allows for faster time-resolved experiments. The detector will be used in the energy range 15-35 keV. At the higher photon energies the Si sen-sor will be less efficient due to lower absorption. It is preferred that the detector can be upgraded to a high-Z sensor if this technology becomes available. The MYTHENIII electronics is prepared for such an upgrade. No other available systems offer this upgradability.
Intern ID : 1

5.1.1 Formål

Kontraktens hovedformål : Varer
Primær klassifikation ( cpv ): 38432300 Røganalyseringsapparat

5.1.2 Udførelsessted

Postadresse : Fotongatan 8
By : Lund
Postnummer : 22484
Landsdel (NUTS) : Skåne län ( SE224 )
Land : Sverige
Yderligere oplysninger :

5.1.6 Generelle oplysninger

Udbuddet er omfattet af aftalen om offentlige udbud (GPA) : ja

5.1.10 Tildelingskriterier

Kriterium :
Type : Pris
Navn : Pris
Beskrivelse : The price from the supplier is crucial.
Vægtning (procentdel, præcis) : 100
Beskrivelse af den metode, der skal anvendes, hvis vægtningen ikke kan udtrykkes ved hjælp af kriterier :
Begrundelse for ikke at angive vægtningen af tildelingskriterierne :

5.1.12 Udbudsvilkår

Oplysninger om klagefrister : Complaint that the Contracting Authority, contrary to the Public Procurement Act, has concluded a contract without prior publication of a contract notice in the European Union Official Journal must be submitted no later than 30 calendar days from the date after a contract award notice has been published by the Contracting Authority in the European Union Official Journal and that contract award notice includes the grounds for the decision to award the contract directly, cf. lov om Klagenævnet for Udbud (Complaints Board for Tenders) § 7, section 3.

5.1.15 Teknikker

Rammeaftale :
Ingen rammeaftale
Oplysninger om det dynamiske indkøbssystem :
Intet dynamisk indkøbssystem

5.1.16 Yderligere oplysninger, mægling og gennemgang

Organisation med ansvar for klager : Klagenævnet for Udbud
Organisation, der leverer oplysninger om den generelle lovgivningsramme angånde skatter på det sted, hvor kontrakten skal udføres : Konkurrence- og Forbrugerstyrelsen
Organisation, der leverer supplerende oplysninger om udbudsproceduren : Danmarks Tekniske Universitet - DTU
Organisation, der sikrer adgang til udbudsdokumenterne offline : Danmarks Tekniske Universitet - DTU
Organisation, hvis budget anvendes til at betale for kontrakten : Danmarks Tekniske Universitet - DTU
Organisation, der udfører betalingen : Danmarks Tekniske Universitet - DTU
Organisation, der underskriver kontrakten : Danmarks Tekniske Universitet - DTU
TED eSender : Mercell Holding ASA

6. Resultater

Værdien af alle kontrakter tildelt i denne bekendtgørelse : 730 000 Schweizisk franc
Direkte tildeling :
Begrundelse for direkte tildeling : Kontrakten kan kun tildeles af en bestemt økonomisk aktør på grund af manglende konkurrence af tekniske årsager
Anden begrundelse : This detector was developed by the detector group at the Paul Scherrer Institute (PSI) and constitutes the latest generation of a successful series of microstrip detectors. Previous generations have been commercialized by a PSI spin-off company, however the latest generation is not available commercially. The market has been surveyed through contact with the PSI spin-off company (DECTRIS AG) and via communications with staff at international synchrotron sources operating or installing similar detector systems on their instruments. The latest generation shows improved specifications across the board compared to the second, more than a decade old, generation. The improvements will be essential in building a competitive instrument. Other justification: There is lack of competition due to technical reasons, cf. § 80, subsection 3, no. 2 in the Danish Public Procurement Law. The contract is awarded to the Paul Scherrer Institute (PSI) as the detector from the Paul Scherrer Institute (PSI) is the only detector that can meet DTU's requirements.

6.1 Resultat delkontrakt-ID : LOT-0000

6.1.2 Oplysninger om vinderne

Vinder :
Officielt navn : Paul Scherrer Institute
Tilbud :
Tilbud – Identifikator : 375178
ID for delkontrakt eller gruppe af delkontrakter : LOT-0000
Kontraktoplysninger :
Identifikator for kontrakten : 6722
Titel : Agreement on MYTHENIII microstrip detector system
Datoen for udvælgelsen af det vindende tilbud : 20/09/2024
Kontrakten tildeles som led i en rammeaftale : nej
Organisation, der underskriver kontrakten : Danmarks Tekniske Universitet - DTU

8. Organisationer

8.1 ORG-0001

Officielt navn : Danmarks Tekniske Universitet - DTU
Registreringsnummer : 30060946
Postadresse : Anker Engelunds Vej 1
By : Kgs. Lyngby
Postnummer : 2800
Landsdel (NUTS) : Københavns omegn ( DK012 )
Land : Danmark
Enhed : Marianne Dauding
Telefon : +45 33344398
Internetadresse : https://www.dtu.dk/
Denne organisations roller :
Køber
Organisation, der leverer supplerende oplysninger om udbudsproceduren
Organisation, der sikrer adgang til udbudsdokumenterne offline
Organisation, der underskriver kontrakten
Organisation, hvis budget anvendes til at betale for kontrakten
Organisation, der udfører betalingen

8.1 ORG-0002

Officielt navn : Klagenævnet for Udbud
Postadresse : Nævnenes hus, Toldboden 2
By : Viborg
Postnummer : 8800
Landsdel (NUTS) : Østjylland ( DK042 )
Land : Danmark
Telefon : +45 35291000
Denne organisations roller :
Organisation med ansvar for klager

8.1 ORG-0003

Officielt navn : Konkurrence- og Forbrugerstyrelsen
Postadresse : Carl Jacobsens Vej 35
By : Valby
Postnummer : 2500
Landsdel (NUTS) : Københavns omegn ( DK012 )
Land : Danmark
Telefon : +45 41715000
Denne organisations roller :
Organisation, der leverer oplysninger om den generelle lovgivningsramme angånde skatter på det sted, hvor kontrakten skal udføres

8.1 ORG-0004

Officielt navn : Paul Scherrer Institute
Postadresse : Forschungstrasse 111
By : Villigen
Postnummer : 5232
Landsdel (NUTS) : Aargau ( CH033 )
Land : Schweiz
Telefon : +41563103574
Denne organisations roller :
Tilbudsgiver
Vinder af disse delkontrakter : LOT-0000

8.1 ORG-0005

Officielt navn : Mercell Holding ASA
Registreringsnummer : 980921565
Postadresse : Askekroken 11
By : Oslo
Postnummer : 0277
Landsdel (NUTS) : Oslo ( NO081 )
Land : Norge
Enhed : eSender
Telefon : +47 21018800
Fax : +47 21018801
Internetadresse : http://mercell.com/
Denne organisations roller :
TED eSender

11. Oplysninger om bekendtgørelsen

11.1 Oplysninger om bekendtgørelsen

Bekendtgørelsens ID : 7f54e11b-7afc-4251-99b4-40121fa21df3 - 01
Formulartype : Forudgående underretning om direkte tildeling
Bekendtgørelsestype : Bekendtgørelse med henblik på frivillig forudgående gennemsigtighed
Afsendelsesdato for bekendtgørelsen : 22/10/2024 08:00 +00:00
Dato for afsendelse af bekendtgørelsen (eSender) : 22/10/2024 08:00 +00:00
Bekendtgørelsens officielle sprog : dansk

11.2 Oplysninger om offentliggørelsen

Bekendtgørelsesnummer : 00642054-2024
EUT-S-nummer : 207/2024
Offentliggørelsesdato : 23/10/2024